NOTE: The Temperatures and Air Volumes listed are base settings only. Your application may require a ± 15% adjustment from the values listed. If machine speed is adjusted Temperature and/or Air Volume may need adjusted also.
Note: If your machine Serial Number is N4120250007 or earlier, contact AirWave Technical Support for settings.
LIGHT DUTY
Film Size | Speed | Heat | Air Volume |
---|---|---|---|
Small Pillow (4x8) | V4 | 58-60% | 13-15% |
Medium Bubble (4 chamber) | V4 | 58-60% | 45-48% |
INDUSTRIAL DUTY
Film Size | Speed | Heat | Air Volume |
---|---|---|---|
Small Pillow (4x8) | V4 | 65-75% | 13-15% |
Medium Bubble (4 chamber) | V4 | 65-75% | 75-80% |
HEAVY DUTY
Film Size | Speed | Heat | Air Volume |
---|---|---|---|
Small Pillow (4x8) | V4 | 80% | 10-15% |
Medium Bubble (4 chamber) | V4 | 80% | 45-48% |