NOTE 1: The Temperatures and Air Volumes are to be used with a 26 ft/min speed and are base settings only. Your application may require a ± 15% adjustment from the values listed. If machine speed is adjusted Temperature and/or Air Volume may need adjusted also.


NOTE 2:  The Air Volumes listed below are to be used with machines with Serial Numbers starting with 2F12020 or earlier.  For Serial Number starting with F22020 or later reduce the Air Volume by 6%


SMALL PILLOW (4" x 8")

Temperature: 390°

Air Volume: 25%


MEDIUM PILLOW (6" x 8")

Temperature: 390°

Air Volume: 25%


LARGE PILLOW (8" x 8")

Temperature: 390°

Air Volume: 18%


MEDIUM BUBBLE (4 Chamber)

Temperature: 390°

Air Volume: 55%


TUBE BUBBLE (1 Chamber)

Temperature: 390°

Air Volume: 40%


Small Bubble (8 Chamber)

Temperature: 390°

Air Volume: 60-65%


Mini Bubble (11 Chamber)

Temperature: 390°

Air Volume: 60-65%